You can help protect yourself from scammers by verifying that the contact is a microsoft agent or microsoft employee and that the phone number is an official microsoft global customer service number. Buy hp 462860b21 smart array p410 zm 2ports int pcie x8 fio sas controller 462860b21. Without the proper safety precautions, use of write cache on physical drives could cause data loss in the event of power failure. Hp smart array p812 controller onboard expander firmware was updated to version 3. The server boots and i can start up linux mint from usb, but when i tried to install it to a hard drive, machine reported no drives found. Raid levels on p410 array controller hewlett packard. Zhuo mao zm r6200c for macbook pro logic board repair, 2011 gpu issue 8202915 duration. In 16bay systems there is usually a p410 along with a p410i controller. Hp smart array controllers for hp proliant servers user guide. Smart array controllers and smart host bus adapters hpe. I reinserted each disk one by one, having one disk in on bootup allowed the controller to detect the old configuration from a single disk and then decided that the remaining were missing, i tried connecting them all at once after the first disk and it went back to 0 volumes, inserted them in one by one took ages as you know how long these servers take to boot. We are leading manufacturer of hp server raid controller.
I found that the write caching was disabled because there was no onboard battery on the controller. Smart array controllers and smart host bus adapters. Hp smart array p410 zm controller storage controller raid sata 1. I was wondering if i would be able to raw disk map the drives through the p410 controller. For updating endurance software, it is necessary to execute the following 2 steps. Hp smart array p410 raid controller 6g sas 3g sata 512 mb fbwc cache, pcie 462919001 low profile. Langsame raid performance hp p410i controller administrator. The lowprofile, halfheight card has 8 ports and utilizes ddr2533 memory. However the raid controller is not playing ball, on boot it recognises the drives, however at 0. Apr 28, 2012 thanks for the guide, and helping me find prtg, how awesome is that software. Drivers for hpe smart array p410 controller hpe support center.
Hp smart array p410 raid controller stops working after. Hp proliant dl180 server smart array p410 controller accubattery duration. I have 4 drives to setup as a raid 5 configuration but cannot figure out how to do this. The latest version of primergy ftmodel hotfix for endurance software v6. We purchased an hp ml350 g6 server with a p410i raid controller. Are you looking for a cost effective, enterpriseclass controller for internal attached drives without occupying a pcie expansion slot. Hp smart array p212 controller the hp smart array sa p212 is an entrylevel pcie sas raid controller. Hp smart array controller family hp smart array p222 controlleradvanced raid functionality with standard 512 mb fbwc the hp smart array p222 is a pcie 3.
You also need to disable the build in raid function on the microserver bios otherwise the p410 card doesnt complete the bios boot. Unfollow hp smart array p410 controller to stop getting updates on your ebay feed. Most viewed solutions for hp smart array p410i controller hp support center. Raid 6 adg raid 60 advanced capacity expansion mirror splitting and recombining in offline mode drive erase. The hp smart array p410 is an 8 port serial attached scsi sas raid controller. Hp smart array controllers do not support boot volumes exceeding 2. When the controller displays press to run the option rom configuration for arrays utility, press f8. Trying to make a hp smartarray p410 work in a consumer. There are a lot of software on hp site for this controller.
Hp 487204b21 pciexpress x8 sata sas smart array p8121g fbwc raid controller card. The hpe ssd smart path feature included in the smart array software stack improves ssd read for all raid levels and raid 0 write operations by optimizing the path to each ssd attached to the controller. To ensure data is properly protected, use redundant power supplies and uninterruptible power supplies. Hp smart array p420i controller storage controller raid. The hpe smart array e208ia sr gen10 controller, supporting 12 gbs sas and pcie 3. We had the same problem with hp bl460 g6 it has the same p410i raid controller and hitachi 1tb travelstar 7k drives. Oct 20, 2017 tech support scams are an industrywide issue where scammers trick you into paying for unnecessary technical support services. Addition of the flash backed cache upgrade enables array expansion, logical drive extension, raid migration, and stripe size migration. Hp raid controllers on the intel 2600gz platform p212 and.
And yes, it can be added when raid is already set up without losing data. Hp smart array p212 zm is known to work flawlessly in the microserver and it connects directly to the standard sff8087 cable coming from the hdd backplane rerouting of the hdd sas cable is required to reach the connector on the controller 1. Expand raid 5 hp smart array p410i controller hewlett. To support some controller features, the controller may also require a hardware configuration that includes the following cache array accelerator options. Raid controllers free delivery possible on eligible purchases. The option rom messages will go through each raid controller installed on the system. I have a proliant dl380 g6, and want to know what the maximum hard drive size is for the smart array p410i controller. Family data sheet hp proliant gen8 smart array controllers. Hp smart array p410i controller raid configuration.
Theres no raid setup utility when the system boots. Jul 31, 2009 however, here is what you need to know the p410 raid controller must have memory if you want to present all 12 drives down as jbod to solaris to be managed via zfs. The advantage of p400 is that it does not require a software key for raid 6 like the p410 and newer ones do. I wont to monitor the raid if hdd are ok, if not than send me some message. Trying to make a hp smartarray p410 work in a consumer grade.
Features 7 for registration procedures, see the configuring arrays for hp smart array controllers reference guide available on the controller documentation cd or the acu product page on the hp website. Hewlett packard enterprise hpe smart array p410 zm controller storage controller sata 3gbs sas 6gbs low profile 6 gbits raid 0 1 10 pcie 2. When activated with a registered license key, saap 1. Hp smart array p420i controller storage controller raid sata 6gbs sas 6gbs pcie 3.
Hp p411 sassata raid controller 462919 578229b21 my cart 0 items. The plan being to create a raid 5 array across the 3 drives to give me circa 5. Took out a 320gb stock drive out of a new notyetdeployed hp compaq 6530b laptop, put it into the tray and the p410i raid controller recognized it and offered to create a raid1 volume. Hp smart array controller driver for solaris 10 x86x64 systems. Product bulletin, research or buy hp printers, desktops, laptops, servers, storage, enterprise solutions and more at the official hewlettpackard website. Hp proliant dl180 server smart array p410 controller. Dell battery pack fur perc storage controller perc 5i, perc 6. Hp proliant dl180 server smart array p410 controller accubattery. I just purchased 2 ml350 g6 servers and i added a 2 bay lff cage total of 8 lff drives. Can anyone tell me how to get raid level 5 on a proliant p410 controller. Hp p410 raid controller and ssd oletho oct 15, 20 8. Raid configuration via kvm on a dell server idrac h310 h710 h730 raid configuration via kvm on a dell server idrac h200 graphical raid configuration using the kvm ilo on hp servers p410.
Hp smart array p212 controller hp smart array p410 controller hp smart array p411 controller hp smart array p711m controller hp smart array p812 controller. Authorized retail dealer of hp server raid controller hp p410 256 smart array controller, hp h222 host bus adapter controller, hp h220 sata 3gb raid controller and hp smart array controller offered by radical technologies private limited, mumbai, maharashtra. Solved raid issue with hp p410 and disks in wrong order. The p410 is designed for raid applications and can be upgraded with the 512mb batterybacked write cache bbwc or 512mb 1gb flashbacked write cache fbwc and the smart array. Tech support scams are an industrywide issue where scammers trick you into paying for unnecessary technical support services.
Retired products sold prior to the november 1, 2015. The hp smart array p212 is hps entry level pci express pcie serial attached scsi sas raid controller. Jul 28, 2017 hp proliant dl180 server smart array p410 controller accubattery duration. Hp smart array p410i controller raid configuration youtube. Hp smart array p410zm controller storage controller raid. As mentioned earlier, with modern firmware, you can use any disks you want. Hp smart array p410 raid controller management server. I have on the server hp proliant dl180 g6 installed esxi 5. Access product support documents and manuals, download drivers by. Intel raid premium features key compatible with intel raid controllers and intel raid modules.
Quickspecs hp smart array p410 controller standard features. The low profile, half height card has 8 ports and utilizes ddr2266 memory. Hp p410 raid controller and sata drives not compatible. Fujitsu recommends that customers update endurance software. Saap is a collection of additional and advanced controller features embedded in the firmware of select smart array controllers. How to configure raid 5 on hp proliant dl380 g7 youtube. I checked the array controller in the production hp ml350g6 with a p410i raid controller, 256mb onboard cache. Ist ein ubertragen eines mit hpe smart array p410 controller. Hp smart array p410 controller hewlett packard enterprise.
Same direct fan out hotswap with raid controller bays. Hp smart array p212256 controller sas raid controller pciexpress renewed lsi logic sas92608i sgl raid 8port int 6gb sassata pcie 2. If you have the p410 256mb controller model no bbwc then you cant do it without recreating the raid5 and losing the data. Zhuo mao zm r6200c for macbook pro logic board repair. Raid controller hp smart array p410 p222 documentation. Bear in mind that you can also migrate one of your current raid 1s to raid 10 by adding more disks to it assuming you have a cache battery. Hp smart array p410 controller hp smart array p411 controller hp smart array p711m controller hp smart array p812 controller. Hp proliant dl180 server smart array p410 controller accu. Configuring arrays on hp smart array controllers reference guide. Ive just got myself an hp ml110 quad core xeon 16gb, a hp p410 raid controller, and 3 western digital red 3tb drives. P410 controllers must always be connecting to something. I have not tried any suggestions yet as we are working on getting temporary systems working as they use bespoke software. I found that the write caching was disabled because there.
One small note, if youve been using a mirrored set of disks using the build in microserver hardware, the p410 card wont recognise it. Hp 1 gb 1024 mb flash backed write cache fbwc modul fur p410. Hp p410i raid controller terrible sequential write. Hp smart array p410 raid controller 6g sas 3g sata 512 mb. Because the nvidia raid controller, is unstable with sata3wd5000aakx hard drive in raid 0 it is fast i admit i made some test, and the 2hdd raid 0 and the 3hdd raid 0 has a same speed 160mbs, and 3hdd raid 5 had worse reading speed, as my old sata1 raid 0 array ther is another option i can choose between 2 raid controller.
I have a question about hp p410 raid smart array controller card. Tested memory list report for intel raid controller srcu42e. Few days ago i installed hitachi hgst ultrastar 7k6000 6tb 7200rpm 128mb hus726060al5214 0f22811 3. If you order the p410 zm you will only be able to create. Acu software will display it in the controller information section. Hp smart array p410 raid controller stops working after falls. After updating the firmware on a smart array p410, p410i, or p212 zero memory zm controller from version 3. I checked the bios and it shows the raid controller as the primary boot device. However, you should be aware that sata disks on that controller will downshift to 3. Also, the p410 and p410i was later upgraded via firmware to enhance features and capabilities, but it did so by making sacrifices in compatibility with nonhp hardware which is fine with hp, they dont sell their cards for nonhp servers. Configuring arrays on hp smart array controllers reference. Maybe someone had success with hp p410 and other sata drives.
Hardware installed remotely and it is difficult to reach noc every week to check drives status. I separate the raid controller irq to 5 usually, keeping the nics around 7 and the usbidracilo junk on higher 1011 call me old school but i still believe it matters. P410i smart array controller sata drive recommendations of. Batteriemodule kommen beispielsweise im zusammenhang mit raidcontroller batterien zum einsatz. Hewlett packard enterprise hpe smart array p420i raid.